Composition
Switchable volt. connection from module/coupling to mounting rail
Shock resistance acc. to IEC 60512-6-3
250 ms-2
Vibration resistance acc. to IEC 60512-6-4
50 ms-2 sinusoidal (9…500 Hz)
Humidity
0...93 % rel. humidity
Housing main material
PA UL 94 V0
PA 66 UL V0 E63957
Insulation cross-section, max.
1.6 mm
Category
Cat.6A / Class EA (ISO/IEC 11801 2010)
Contact material
Spring steel
Ni 1.2 µm
Contact surface
Au ≥ 0.8 µm
Connection diameter, solid
0.4...0.64 mm
Conductor connection cross-section, solid (AWG)
AWG 24...AWG 22
Connection diameter, flexible
0.48...0.76 mm
Conductor connection cross-section, flexible (AWG)
AWG 26...AWG 22
Sheath diameter, min.
5.5 mm
Sheath diameter, max.
10 mm
Plugging cycles
750 (RJ45)
Ability to reconnect
≥ 10 cycles for AWG 23-26
≥ 4 cycles for AWG 22